How to deal with oil leakage of Luoying rubber joint

Time: 04-06 󰃯 Reading times: 541 󰃳 Editor in charge: The sea 󰃗 Column: product focus

Introduction: The more common the rubber joint is used, the more difficult it will be for customers to consult. For example, a customer said a few days ago that the applied rubber joint had oil leakage. What is the reason? How to deal with it? Now let's introduce how the rubber joint seeps oil

Rubber joint The more common the application is, the more difficult it will be for customers to consult. For example, a customer said a few days ago that the applied rubber joint had oil leakage. What is the reason? How to deal with it? Now net knitting to introduce how to deal with the rubber joint oil leakage.
The leakage of rubber joint may cause problems of rubber joint, and it may also be the wrong installation method of rubber joint, cracking of rubber parts and damage of metal flange. Due to careful inspection, the source of the problem is found.
If there is oil leakage in rubber joint, the first thing to do is to shut down the pipeline system. After disassembling the rubber joint carefully, check whether the rubber product is cracked. If there is crack, the wear-resistant joint shall be removed immediately, followed by whether the rubber joint is installed properly, whether the compensation amount of the connector and the pipeline offset is equal, if not, it is proposed The rubber joint parts with suitable length shall be removed and replaced, and the metal flange position of rubber joint shall be checked to see whether the screw is tightened and whether there is any damage, resulting in installation problems.
When there is no problem with the rubber joint, it is necessary to check whether the pipes around the joint are damaged, dropped or cracked. If there is still no problem, the rubber joint should be further decomposed to check whether the fit gap between the joint and flange is too large, whether the rubber joint and the pipe meet is tight, and whether the extension of the rubber joint is too soft or broken. According to the condition, the method of grinding or repairing shall be adopted.
When installing the bolt into the flange, the screw head should be pressed evenly to avoid the screw head extending into the hole. The screw connector should be tightened evenly with a standard wrench. It is not allowed to add points with a point adding rod to make the movable joint slip, slip edge and fracture. Regular maintenance should be carried out to prevent loosening and causing disc detachment or leakage.
The application or storage of rubber joint should prevent high temperature, active oxygen, oil and strong acid and alkali natural environment. It is not allowed to be exposed to the sun or exposed to the wind. It is forbidden to brush paint and coil thermal insulation material on the surface of connector. Due to the aging of rubber products, timely inspection and replacement should be carried out.
The service life of rubber joint is about 3-5 years. When this application period is up and down, attention should be paid to immediate removal and replacement, in order to prevent accidents, leading to greater damage.